Product parameters:
1: Output voltage: AC 12V.
2: Input voltage: DC 12V.
3: Applicable voltage: DC 8V~15V.
4: Module output: AC square wave.
5: The module input has anti-reverse connection protection.
6: Output frequency: 50Hz, can be fine-tuned up and down.
7: Output current: maximum 10A, please install cooling equipment when using high current.
8: Output power: up to 200W with cooling equipment, up to 100W without cooling equipment.
9: Module weight: 19 grams.
10: Working humidity: 5%~95%RH.
11: Working temperature: -25℃~85℃.
12: Module size: 66*40*16mm.
 
Power Requirements:
Input DC 12V, minimum voltage 8V, maximum voltage 15V.
Power recommendation: input power = maximum output power x 1.5.
 
Precautions:
(1) The module does not have a voltage regulation function, and the output voltage is also low if the input voltage is low;

(2) In order to ensure the normal operation of the module, please connect a fuse in series at the input end by yourself, use a 10A fuse within the output power of 100W, and use a 20A fuse within the output power of 200W;

(3) Choose a suitable transformer according to your own needs. Generally, the power of 10W is required to be greater than 15W, and the output of 100W is more suitable to choose 150W. The power of the transformer should be larger than the actual power used;

(4) Please use the transformer produced by the regular manufacturer, otherwise the module may be damaged;

(5) Do not use leakage inductance transformers and high-frequency transformers, otherwise the module will be damaged;

(6) The no-load output voltage depends on the transformation ratio of the transformer and the input battery voltage. If the no-load is normal, the power of the transformer is generally reduced due to the serious reduction of the load. The insufficient power here includes the following situations: the transformer itself is a small power Transformers, and high-power multi-winding transformers, choose 12V among them, because the transformer manufacturers do it according to the total power distribution.

For example: a 500W transformer has dual 28V windings, 9V windings, and dual 12V windings. The manufacturer may allocate the main 400W to the dual 28V windings, and the remaining 100W to the 9V windings and dual 12V windings. The inverter uses 12V, and it can't produce high power at all, even 100W can't be achieved. In addition, when the load drops, it is necessary to consider whether the input wire is too thin, the battery is too small, etc. Small batteries, thin wires, and small transformers cannot produce the power of the board. The transformation ratio also affects the output voltage. At this time, the most obvious manifestation is that the no-load voltage is low. For example, a black and white TV transformer that uses 220V to double 17V can only output a voltage of about 155V.




Product parameters:
1: Output voltage: AC 12V.
2: Input voltage: DC 12V.
3: Applicable voltage: DC 8V~15V.
4: Module output: AC square wave.
5: The module input has anti-reverse connection protection.
6: Output frequency: 50Hz, can be fine-tuned up and down.
7: Output current: maximum 10A, please install cooling equipment when using high current.
8: Output power: up to 200W with cooling equipment, up to 100W without cooling equipment.
9: Module weight: 19 grams.
10: Working humidity: 5%~95%RH.
11: Working temperature: -25℃~85℃.
12: Module size: 66*40*16mm.
 
Power Requirements:
Input DC 12V, minimum voltage 8V, maximum voltage 15V.
Power recommendation: input power = maximum output power x 1.5.
 
Precautions:
(1) The module does not have a voltage regulation function, and the output voltage is also low if the input voltage is low;

(2) In order to ensure the normal operation of the module, please connect a fuse in series at the input end by yourself, use a 10A fuse within the output power of 100W, and use a 20A fuse within the output power of 200W;

(3) Choose a suitable transformer according to your own needs. Generally, the power of 10W is required to be greater than 15W, and the output of 100W is more suitable to choose 150W. The power of the transformer should be larger than the actual power used;

(4) Please use the transformer produced by the regular manufacturer, otherwise the module may be damaged;

(5) Do not use leakage inductance transformers and high-frequency transformers, otherwise the module will be damaged;

(6) The no-load output voltage depends on the transformation ratio of the transformer and the input battery voltage. If the no-load is normal, the power of the transformer is generally reduced due to the serious reduction of the load. The insufficient power here includes the following situations: the transformer itself is a small power Transformers, and high-power multi-winding transformers, choose 12V among them, because the transformer manufacturers do it according to the total power distribution.

For example: a 500W transformer has dual 28V windings, 9V windings, and dual 12V windings. The manufacturer may allocate the main 400W to the dual 28V windings, and the remaining 100W to the 9V windings and dual 12V windings. The inverter uses 12V, and it can't produce high power at all, even 100W can't be achieved. In addition, when the load drops, it is necessary to consider whether the input wire is too thin, the battery is too small, etc. Small batteries, thin wires, and small transformers cannot produce the power of the board. The transformation ratio also affects the output voltage. At this time, the most obvious manifestation is that the no-load voltage is low. For example, a black and white TV transformer that uses 220V to double 17V can only output a voltage of about 155V.




Choose a ranking for this item. 1 star is the worst and 5 stars is the best.





NOTE: HTML tags are not allowed.
NOTE: Reviews require prior approval before they will be displayed

* Delivery Time.
We need 1-2 days to process your order before shipping.There are two shipping methoed. Fast Delivery: The delivery time for US, European countries the delivery will take 3-5 days.Slow Delivery: The delivery time for US, European countries the delivery will take 10-15 days.
* Tracking information.
After we ship package, customer receive automatic email with tracking details.
* Lost Package Policy.
If a package did not arrive in 4 weeks after the shipping date, then this package is treated as Lost. In this case a new package will be shipped to the customer provided we are able to give the same items as those purchased by the customer. If we are not able to provide the same items to substitute the lost ones we will either propose to the customer similar items or refund their cost as it will be mutually agree with the customer. If one or more items neither the same nor similar are available to be shipped, the customer can request to cancel the order entirely, thus the total cost of the order including shipping and handling cost will be fully refunded.

payment
Copyright © 2024 Eletechsup All Rights Reserved.